-- HELP SCREEN -- This screen is presented for calculating required orifice area for GAS/VAPOR Sizing. After calculated area is determined, manually enter selected orifice area and API letter designation, for automatic calculat- ion of maximum flow capacity, reactive force at valve oulet, and noise level at a distance of three feet from discharge at outlet. Use the ENTER key to move through the input fields for changing any data for recalculations. Function key F1 will calculate orifice area. When calculation is completed, press F8 to store data for later retrieval or F2 for API spec sheet. ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» ÍÍÍ͹ UNIT CONVERSIONS ÌÍÍÍÍ ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÑÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º TO CONVERT ³ INTO ³ MULTIPLY BY º ÌÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍØÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ͹ º Millimeters Water Column ³ in wc ³ 0.0394 º º (mm wc) ³ oz ³ 0.0227 º º ³ psi ³ 0.001421 º ÇÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄĶ º Millibars (mb) ³ in wc ³ 0.4019 º º ³ oz ³ 0.2320 º ÇÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄĶ º Kilograms/cm2 (kg/cm2) ³ oz ³ 227.60 º º ³ psi ³ 14.22 º ÇÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄĶ º Liters per Hour (l/h) ³ gpm (US) ³ 0.0044 º º Cubic Meters/Hour (m3/h) ³ gpm (US) ³ 4.403 º º Kilograms/Hour (kg/h) ³ gpm (US) ³ 1/ 227.1 x G º º Imperial Gallons/Minute ³ gpm (US) ³ 1.201 º ÇÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄĶ º kg/h ³ scfm ³ 13.93/ M º º Nm3/h ³ scfm ³ 0.6216 º º Nm3/min ³ scfm ³ 37.30 º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÏÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ NOTES: G = Specific Gravity of liquid M = Molecular Weight of gas If flow is expressed in actual volume, such as cfm or acfm, this flow can be converted to scfm as follows: 14.7 + p 520 scfm = (acfm) x ÄÄÄÄÄÄÄÄ x ÄÄÄÄÄÄÄÄ 14.7 460 + t Where: p = gauge pressure in psig t = temperature in deg. F acfm = actual cubic feet per minute ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º REACTIVE FORCE CALCULATION º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ The formula for determining reaction forces in an Open-Discharge system TO ATMOSPHERE through an elbow and vertical discharge pipe was revised in 1989 to include the additional forces generated at the valve outlet area. In order to determine total reactive forces, the following should be added to the calculated force to obtain the actual force: ( Ao x P2 ), based on schedule 40 tailpipe. VALVE OUTLET AREA (Ao) Ao x P2 2" 3.356 sq. in. 49.33 lbs. 3" 7.393 sq. in. 108.68 lbs. 4" 12.730 sq. in 187.13 lbs. 6" 28.890 sq. in. 424.68 lbs. 8" 50.027 sq. in. 735.40 lbs. 10" 78.854 sq. in. 1159.15 lbs. 12" 113.040 sq. in. 1661.69 lbs. EXAMPLE: If calculated reactive force is 832.40 lbs., and the size valve selected, determined by orifice calculation is 3" Inlet x 4" Outlet, add 832.40 + 187.13 for an actual reactive force of 1,019.53 lbs. ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ» º PILOT-OPERATED SAFETY RELIEF VALVES º º º º ORIFICE AREA, SQ. IN. º ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ ³ VALVE SIZE ³ TYPE X33 TYPE X23 TYPE X73 TYPE 226/526 TYPE 727 ÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 1x2, 1-1/2x2 ³ 0.156 (D) 0.326 (F) -- -- -- ³ 0.272 (E) -- -- -- -- 1-1/2x2 ³ -- -- 1.336 -- -- ³ 1-1/2x3 ³ 0.615 (G) 0.838 (H) -- 0.841 (H) -- ³ 2x3 ³ 0.647 (G) 1.371 (J) 2.530 1.375 (J) 0.503 (G) ³ 0.998 (H) 0.785 (H) ³ 1.287 (J) ³ 3x4 ³ 1.487 (J) 3.062 (L) 6.651 3.073 (L) 1.287 (J) ³ 2.218 (K) 1.838 (K) ³ 2.853 (L) ³ 4x6 ³ 3.603 (L) 6.824 (P) 9.629 6.848 (P) 2.853 (L) ³ 4.482 (M) 3.600 (M) ³ 5.185 (N) 4.340 (N) ³ 6.380 (P) ³ 6x8 ³ 12.671 (Q) 17.087 (R) 17.149 (R) 11.050 (Q) ³ 16.000 (R) 6x DUAL 8 ³ 21.520 8x DUAL 8 ³ 29.420 ³ 8x10 ³ 27.813 (T) 27.913 (T) 26.000 (T) ³ 8x DUAL 10 ³ 44.180 X = SERIES 200/400/600/900 POSRV CONVERSION CURVE Altitude to Atmospheric Pressure Altitiude (thousands) Atm. Pressure 1 14.3 2 13.7 3 13.2 4 12.7 5 12.2 6 11.8 7 11.3 8 10.9 9 10.5 10 10.1 11 9.7 12 9.3 13 9.0 14 8.8 15 8.5 END OF HELP Press ESC to return to screen.